weblogic.nodemanager.NodeManagerException: [WindowsProcessControl: online: failed to read pid for server 'TestServer' - reason - [WindowsProcessControl: online: failed to read pid for server 'TestServer' - reason - ERROR Creating Process. Error No:3]]

Oracle Community | 666705 | 1 decade ago
  1. 0

    WindowsProcessControl: online:  failed to read pid for server

    Oracle Community | 1 decade ago | 666705
    weblogic.nodemanager.NodeManagerException: [WindowsProcessControl: online: failed to read pid for server 'TestServer' - reason - [WindowsProcessControl: online: failed to read pid for server 'TestServer' - reason - ERROR Creating Process. Error No:3]]
  2. 0

    Unable con run Admin server / node manager / manager servers

    Oracle Community | 1 decade ago | 3004
    weblogic.nodemanager.NodeManagerException: [Could not execute command start for> server sa via the Node Manager - reason: [CommandInvoker: Failed to sendcommand:> 'online to server 'sa' to NodeManager at host: '2.0.0.1:5555' withexception FATAL> Alert:BAD_CERTIFICATE - A corrupt or unuseable certificate was received..Please> ensure that the NodeManager is active on the target machine.]
  3. 0

    Unable con run Admin server / node manager / manager servers

    Google Groups | 1 decade ago | Julio Saura
    weblogic.nodemanager.NodeManagerException: [Could not execute command start for server sa via the Node Manager - reason: [CommandInvoker: Failed to send command: 'online to server 'sa' to NodeManager at host: '2.0.0.1:5555' with exception FATAL Alert:BAD_CERTIFICATE - A corrupt or unuseable certificate was received.. Please ensure that the NodeManager is active on the target machine].]
  4. Speed up your debug routine!

    Automated exception search integrated into your IDE

  5. 0

    Keep on getting exception when trying to start ManagedServer wit h NodeManager in wls 7.0

    Oracle Community | 1 decade ago | 3004
    weblogic.nodemanager.NodeManagerException: [Could not execute command start for server managedServer via the Node Manager - reason: [CommandInvoker: Failed to send command: 'online to server 'managedServer' to NodeManager at host: 'localhost:5555' with exception FATAL Alert:HANDSHAKE_FAILURE - The handshake handler was unable to negotiate an acceptable set of security parameters.. Please ensure that the NodeManager is active on the target machine].]
  6. 0

    HANDSHAKE_FAILURE problem when starting managed server via NOdeManager

    Oracle Community | 1 decade ago | 3004
    weblogic.nodemanager.NodeManagerException: [Could not execute command start for server managedServer via the Node Manager - reason: [CommandInvoker: Failed to send command: 'online to server 'managedServer' to NodeManager at host: 'localhost:5555' with exception FATAL Alert:HANDSHAKE_FAILURE - The handshake handler was unable to negotiate an acceptable set of security parameters.. Please ensure that the NodeManager is active on the target machine].]

    Not finding the right solution?
    Take a tour to get the most out of Samebug.

    Tired of useless tips?

    Automated exception search integrated into your IDE

    Root Cause Analysis

    1. weblogic.nodemanager.NodeManagerException

      [WindowsProcessControl: online: failed to read pid for server 'TestServer' - reason - [WindowsProcessControl: online: failed to read pid for server 'TestServer' - reason - ERROR Creating Process. Error No:3]]

      at weblogic.nodemanager.WindowsProcessControl.online()
    2. weblogic.nodemanager
      BaseProcessControl.executeCommand
      1. weblogic.nodemanager.WindowsProcessControl.online(WindowsProcessControl.java:148)
      2. weblogic.nodemanager.BaseProcessControl.executeCommand(BaseProcessControl.java:482)
      2 frames
    3. weblogic.nodemanager.internal
      Request.run
      1. weblogic.nodemanager.internal.Request.run(Request.java:179)
      1 frame