Searched on Google with the first line of a JAVA stack trace?

We can recommend more relevant solutions and speed up debugging when you paste your entire stack trace with the exception message. Try a sample exception.

Recommended solutions based on your search

Solutions on the web

via Pentaho BI Platform Tracking by Michael Willig, 1 year ago
3.1.0, build 826 from 2008/09/30 11:29:00) : 2008/12/16 11:04:07 - Append streams.0 - ERROR (version 3.1.0, build 826 from 2008/09/30 11:29:00) : The name of field number 6 is not the same as in the first row received: you're mixing rows with
via Pentaho BI Platform Tracking by Michael Willig, 1 year ago
Invalid layout detected in input streams, rows to append have to be of identical structure The name of field number 6 is not the same as in the first row received: you're mixing rows with different layout. Field [AUDIT_CREATIONDATE Date] does not have the same name as field [AUDIT_CREATIONDATE Date].
via Pentaho BI Platform Tracking by Jimmy Skaria Abraham, 1 year ago
Invalid layout detected in input streams, rows to append have to be of identical structure The data type of field #1 is not the same as the first row received: you're mixing rows with different layout. Field [CONTACT_OWNER_ID Number] does not have the same data type as field [CONTACT_OWNER_ID Integer(10)].
via Pentaho BI Platform Tracking by Jimmy Skaria Abraham, 1 year ago
Invalid layout detected in input streams, rows to append have to be of identical structure The data type of field #1 is not the same as the first row received: you're mixing rows with different layout. Field [CONTACT_OWNER_ID Number] does not have the same data type as field [CONTACT_OWNER_ID Integer(10)].
via Pentaho BI Platform Tracking by Jimmy Skaria Abraham, 1 year ago
Invalid layout detected in input streams, rows to append have to be of identical structure The data type of field #1 is not the same as the first row received: you're mixing rows with different layout. Field [CONTACT_OWNER_ID Number] does not have the same data type as field [CONTACT_OWNER_ID Integer(10)].
via Pentaho BI Platform Tracking by Jimmy Skaria Abraham, 1 year ago
Invalid layout detected in input streams, rows to append have to be of identical structure The data type of field #1 is not the same as the first row received: you're mixing rows with different layout. Field [CONTACT_OWNER_ID Number] does not have the same data type as field [CONTACT_OWNER_ID Integer(10)].
org.pentaho.di.core.exception.KettleRowException: 2008/12/16 11:04:07 - Append streams.0 - ERROR (version 3.1.0, build 826 from 2008/09/30 11:29:00) : The name of field number 6 is not the same as in the first row received: you're mixing rows with different layout. Field [AUDIT_CREATIONDATE Date] does not have the same name as field [AUDIT_CREATIONDATE  Date].
2008/12/16 11:04:07 - Append streams.0 - ERROR (version 3.1.0, build 826 from 2008/09/30 11:29:00) :	at org.pentaho.di.trans.step.BaseStep.safeModeChecking(BaseStep.java:1648)	at org.pentaho.di.trans.steps.append.Append.checkInputLayoutValid(Append.java:149)	at org.pentaho.di.trans.steps.append.Append.processRow(Append.java:87)	at org.pentaho.di.trans.step.BaseStep.runStepThread(BaseStep.java:2664)	at org.pentaho.di.trans.steps.append.Append.run(Append.java:157)